A price is a price of 1 reel (100m).
I send it in the state that I bound a spool with like an image.
Use	I use it in (four of them, two) automotive low-pressure conductive trace.
Characteristic	CPAVS is Sumitomo name of AVS(f).
It is the electric wire which is superior to AVS in flexibility.
JASO D611 conformity
 Heat-resistant class	80 degrees Celsius
The heat-resistant class is conductor best allowable temperature when 10,000 hours were used as an indication at accumulation electricity time
Maker	Sumitomo Wiring Systems
Series	Escalope low pressure electric wire (escalope electric wire type 1) for the CPAVS car
Standard size	1.25 (f)
 Number of the wires/wire diameter (this /mm)	50/0.18
 Conductor calculation cross section (mm2)	1.273
 Conductor outer diameter (mm)	1.5
 Insulator thickness (mm)	0.5
 Finish outer diameter (mm)	2.5-2.6
 Current tolerance in case of 1.25 (f)
 Ambient temperature (℃)	20	30	40	50	60	70
 Current tolerance (A)	24	22	20	17	14	10
※The current tolerance is the electric current that conductor saturation temperature becomes the heat-resistant temperature under each ambient temperature.
※The current tolerance in the image is notation in case of ambient temperature 40 degrees.